OVERVIEW
XBC Series Diesel Fire Pump Unit is an innovative marvel, seamlessly fusing cutting-edge industrial automation control, advanced information processing, and precise mechanical operation technologies. The unit boasts an impressive array of features:
- Automatic Start and Stop: Effortlessly initiates and halts operations without manual intervention, ensuring seamless functionality.
- Automatic Speed Regulation: Intelligently adjusts speed autonomously, optimizing efficiency and performance.
- Automatic Charging: Equipped with sophisticated automatic charging capabilities to maintain optimal operation.
- Parameter Monitoring: Continuously monitors and detects critical parameters, ensuring the highest level of performance and safety.
- Automatic Alarming: Instantly provides alerts to preemptively address potential issues, enhancing safety measures.
- Automatic Inspection: Conducts thorough automatic inspections, maintaining peak operational readiness.
- Remote Control: Empowers users with robust remote control capabilities, facilitating convenient and effective operation.
APPLICATIONS
- Fire Protection Systems:
- Fire Hydrant Systems
- Sprinkler Systems
- Water Spray Cooling Systems
- Foam Systems
- Water Cannon Systems
- Hospital Fire Protection
- Emergency Fire Water Supply
- Fire Systems for Industrial and Civil Buildings
ADVANTAGES
- Multiple Startup Options: Offers a versatile range of startup functions, including manual initiation, remote signal activation, fully automated startup, and emergency manual direct start, ensuring reliability in every situation.
- Automatic Operation in Fire Situations: In the event of receiving a valid fire signal, and encountering power failures, phase loss, or pump malfunction in the electric fire pump system, the diesel fire pump unit springs into action automatically. When normal conditions are restored, the system switches back seamlessly to the electric pump, ensuring uninterrupted protection.
- Fire Signal Feedback: Efficiently transmits fire signals back to the fire control room, enabling comprehensive remote monitoring and management.
- Automatic Shutdown: The intelligent diesel fire pump orchestrates an automatic shutdown with a pre-set delay after the cessation of the fire signal, ensuring safe and efficient operations.
- Self-Charging Voltage Regulation: Utilizes mains electricity for automatic battery charging, ensuring the unit is always ready for action with reliable start-up capabilities.
- Comprehensive Alarm and Protection System: A sophisticated alarm system highlights three startup failures, overspeed, low oil pressure, low booster oil pressure, elevated coolant water temperature, low oil temperature, automatic charging device malfunctions, and fluctuations in battery voltage, as well as low oil levels, ensuring all-round protection.
- Visualization Display System: The intuitive control panel displays crucial information such as diesel engine oil pressure, engine speed, battery charging current, and battery voltage, providing real-time insights for optimal control.
- Integrated Structure: Featuring a streamlined design, the diesel engine and pump are directly coupled using a shared steel base. This compact and cohesive structure enhances performance, minimizes faults and vibrations, and simplifies on-site installation, making it an ideal choice for high-performance requirements.
Product Parameters
TECHNICAL PARAMETER
Pump Operating Range:
- Flow Rate: 100-430 L/S
- Head: 60-185 m
- Transported Media: Designed for ordinary clean water and specialized firefighting foam liquid, ensuring optimal performance and safety in critical situations.
Diesel Engine Operating Range:
- Ambient Temperature: Capable of operating efficiently in a wide range from -25 to 55°C, adapting to various climate conditions.
- Relative Humidity: Can function effectively with humidity levels under <85%, making it suitable for diverse environments.
- Longitudinal Inclination: Functionality is maintained with inclinations up to <10°, providing flexibility in diverse settings.
- No Conductive Dust, Corrosive Gases, or Explosive Hazards: Ensure the surrounding environment is free from conductive dust, corrosive gases, or explosive hazards that could compromise safety or damage metal insulation.
- Altitude and Humidity Adjustments: When ambient temperatures exceed 20°C, or relative humidity surpasses 30%, or altitudes go beyond 1000 meters, it's crucial to adjust the diesel engine power using the manufacturer's detailed data table for peak efficiency.
Control Cabinet Operating Range:
- Power Voltage Fluctuation: Designed to handle voltage fluctuations of ≤±10%, ensuring reliable performance.
- Ambient Temperature: Operational range from -10 to +40°C, allowing non-freezing conditions for optimal functionality.
- Air Relative Humidity: Operates smoothly within 20% to 90% air relative humidity, provided there is no condensation, ensuring consistent performance.
Detailed Photos
![Diesel Engine Multi-Stage Fire Pump Water Pump Diesel Generator Set](//www.micstatic.com/athena/img/transparent.png)
Company Profile
![Diesel Engine Multi-Stage Fire Pump Water Pump Diesel Generator Set](//www.micstatic.com/athena/img/transparent.png)
![Diesel Engine Multi-Stage Fire Pump Water Pump Diesel Generator Set](//www.micstatic.com/athena/img/transparent.png)
![Diesel Engine Multi-Stage Fire Pump Water Pump Diesel Generator Set](//www.micstatic.com/athena/img/transparent.png)
![Diesel Engine Multi-Stage Fire Pump Water Pump Diesel Generator Set](//www.micstatic.com/athena/img/transparent.png)
![Diesel Engine Multi-Stage Fire Pump Water Pump Diesel Generator Set](//www.micstatic.com/athena/img/transparent.png)
![Diesel Engine Multi-Stage Fire Pump Water Pump Diesel Generator Set](//www.micstatic.com/athena/img/transparent.png)
FAQ