OVERVIEW
XBC Series Diesel Fire Pump Unit The XBC Series Diesel Fire Pump Unit is a cutting-edge marvel, seamlessly combining industrial automation technology, advanced information processing, and mechanical operation expertise. Discover its outstanding features:
- Automatic Start and Stop: Effortlessly initiates and halts operations without manual intervention.
- Automatic Speed Regulation: Intelligently adjusts its speed to meet varying demands.
- Automatic Charging: Equipped with a state-of-the-art automatic charging feature to ensure continuous readiness.
- Parameter Monitoring: Continuously monitors crucial parameters for optimal performance.
- Automatic Alarming: Instantly alerts you to any irregularities with its proactive alarm system.
- Automatic Inspection: Conducts thorough self-checks to maintain reliability and safety.
- Remote Control: Offers seamless remote operation, providing unmatched control from a distance.
APPLICATIONS
- Fire Protection Systems:
- Fire Hydrant Systems
- Sprinkler Systems
- Water Spray Cooling Systems
- Foam Systems
- Water Cannon Systems
- Ideal for safeguarding hospitals with specialized fire protection solutions.
- Crucial in providing emergency fire water supply.
- Integral to fire systems in both industrial and civil infrastructures.
ADVANTAGES
- Multiple Startup Options: Boasts a versatile range of startup capabilities: manual initiation, remote signal activation, automatic engagement, and emergency manual direct start for ultimate flexibility.
- Automatic Operation in Fire Situations: Automatically activates upon receiving a valid fire signal, especially valuable when electric systems fail. Seamlessly reverts to electric operation once power is restored, ensuring continuous protection.
- Fire Signal Feedback: Efficiently communicates fire signals to the control room, facilitating remote supervision and management.
- Automatic Shutdown: Automatically ceases operations after fire signals subside, ensuring safety and energy efficiency.
- Self-Charging Voltage Regulation: Ensures the battery is optimally charged using mains power, guaranteeing reliable startup every time.
- Comprehensive Alarm and Protection System: Provides robust protection with alarms for startup failures, overspeed, low pressures, temperature anomalies, charging device issues, and battery voltage concerns, safeguarding the system from potential disruptions.
- Visualization Display System: The sophisticated control panel vividly presents vital data, including engine oil pressure, speed, battery charging current, and voltage, enabling informed decision-making.
- Integrated Structure: Features a meticulously designed integrated structure, where the diesel engine and pump are directly coupled on a common steel base. This compact design ensures exceptional performance with minimal vibration, facilitating hassle-free installation and operation.
Product Parameters
TECHNICAL PARAMETER
Pump Operating Range:
- Flow Rate: Experience a remarkable flow rate ranging from 100 to 430 liters per second, ensuring high-performance delivery.
- Head: Achieve superior water lifting capabilities with a head range spanning 60 to 185 meters.
- Transported Media: Designed for versatility, it handles ordinary clean water as well as specialized firefighting foam liquid seamlessly.
Diesel Engine Operating Range:
- Ambient Temperature: Operates efficiently within a broad ambient temperature spectrum of -25 to 55°C, adapting well to diverse climates.
- Relative Humidity: Functions optimally with relative humidity less than 85%, addressing humidity challenges.
- Longitudinal Inclination: Designed for stability, it performs within a safe longitudinal inclination of less than 10°.
- No Conductive Dust, Corrosive Gases, or Explosive Hazards: Ensure a safe operational environment devoid of conductive dust, corrosive gases, or explosive risks, safeguarding metal insulation and overall safety.
- Altitude and Humidity Adjustments: For environments with ambient temperatures over 20°C, relative humidity exceeding 30%, or altitudes above 1000 meters, tailor the diesel engine power in accordance with the data table provided by the manufacturer.
Control Cabinet Operating Range:
- Power Voltage Fluctuation: Maintains functionality with power voltage fluctuations within an impressive range of ≤±10%.
- Ambient Temperature: Operates reliably in temperatures from -10 to +40°C, excluding freezing conditions.
- Air Relative Humidity: Capable of operating in air relative humidity from 20% to 90%, provided there is no condensation.
Detailed Photos
![750 Gpm Portable Fire Fighting System Water Pump Whole Set Manufacturers Diesel Engine Fire Pump for Fire Truck](//www.micstatic.com/athena/img/transparent.png)
Company Profile
![750 Gpm Portable Fire Fighting System Water Pump Whole Set Manufacturers Diesel Engine Fire Pump for Fire Truck](//www.micstatic.com/athena/img/transparent.png)
![750 Gpm Portable Fire Fighting System Water Pump Whole Set Manufacturers Diesel Engine Fire Pump for Fire Truck](//www.micstatic.com/athena/img/transparent.png)
![750 Gpm Portable Fire Fighting System Water Pump Whole Set Manufacturers Diesel Engine Fire Pump for Fire Truck](//www.micstatic.com/athena/img/transparent.png)
![750 Gpm Portable Fire Fighting System Water Pump Whole Set Manufacturers Diesel Engine Fire Pump for Fire Truck](//www.micstatic.com/athena/img/transparent.png)
![750 Gpm Portable Fire Fighting System Water Pump Whole Set Manufacturers Diesel Engine Fire Pump for Fire Truck](//www.micstatic.com/athena/img/transparent.png)
![750 Gpm Portable Fire Fighting System Water Pump Whole Set Manufacturers Diesel Engine Fire Pump for Fire Truck](//www.micstatic.com/athena/img/transparent.png)
FAQ