OVERVIEW
XBC Series Diesel Fire Pump Unit Step into the future of fire safety with this state-of-the-art marvel! Featuring a harmonious blend of the latest in industrial automation control, refined information processing, and cutting-edge mechanical operation technologies, this pump unit showcases extraordinary characteristics:
- Automatic Start and Stop: Achieve unrivaled operational efficiency with its automatic start and stop features, guaranteeing top-level preparedness at any given moment.
- Automatic Speed Regulation: Enjoy unparalleled adaptability as it intelligently adjusts speed to meet various operational needs, maximizing both efficiency and performance.
- Automatic Charging: Stay charged and ready with its innovative automatic charging feature, ensuring uninterrupted power availability.
- Parameter Monitoring: With vigilant parameter monitoring, this unit ensures optimum performance by detecting and maintaining crucial operational benchmarks.
- Automatic Alarming: Never miss a critical update with its timely automatic alarms, keeping you informed and prepared for any situation.
- Automatic Inspection: Conducts comprehensive automatic inspections, ensuring every component is operating at peak performance.
- Remote Control: Benefit from the ultimate in convenience and adaptability with remote control operations, offering seamless management from afar.
APPLICATIONS
- Fire Protection Systems:
- Fire Hydrant Systems
- Sprinkler Systems
- Water Spray Cooling Systems
- Foam Systems
- Water Cannon Systems
- Hospital Fire Protection
- Emergency Fire Water Supply
- Fire Systems for Industrial and Civil Buildings
ADVANTAGES
- Multiple Startup Options: Experience unmatched flexibility with an array of startup mechanisms including manual, remote signal, automatic start, and an emergency manual direct start, ensuring the utmost in reliability and adaptability for any scenario.
- Automatic Operation in Fire Situations: Effortlessly activates upon receiving a valid fire signal, overcoming challenges such as power outages, phase loss, or pump issues. Seamlessly transitions back to electric mode when systems are restored, maintaining a steadfast defense against fire threats.
- Fire Signal Feedback: Enhance control room operations with seamless fire signal feedback, elevating monitoring and operational auditing to new heights.
- Automatic Shutdown: Ensures resource conservation and safety with a delayed automatic shutdown post-signal disappearance, efficiently managing system resources.
- Self-Charging Voltage Regulation: Rely on consistent power as it self-charges using mains electricity, guaranteeing dependable start-up and continuous operation.
- Comprehensive Alarm and Protection System: Boasts an extensive alarm system for various anomalies including startup failures, overspeed, oil pressure issues, coolant temperature surges, charging failures, and battery voltage irregularities, ensuring complete protection and awareness.
- Visualization Display System: Stay fully informed with a vivid control panel that clearly displays key operational statistics such as oil pressure, engine speed, charging current, and voltage.
- Integrated Structure: Beautifully engineered with a direct coupling between the diesel engine and pump on a unified steel base, this compact design ensures superior performance with minimal vibrations and faults, simplifying on-site installation.
Product Parameters
TECHNICAL PARAMETER
Pump Operating Range:
- Flow Rate: 100-430 L/S
- Head: 60-185 m
- Transported Media: Our state-of-the-art pump is designed to handle ordinary clean water and specialized firefighting foam liquid efficiently, ensuring optimal performance in emergency situations.
Diesel Engine Operating Range:
- Ambient Temperature: -25 to 55°C
- Relative Humidity: Maintain a humidity level of less than 85% for optimal engine performance.
- Longitudinal Inclination: Ensure the inclination is kept below 10° to maintain engine stability.
- No Conductive Dust, Corrosive Gases, or Explosive Hazards: It is crucial to ensure an environment free of conductive dust, corrosive gases, or explosive hazards that could impair metal insulation performance or pose a risk of explosion.
- Altitude and Humidity Adjustments: For optimal diesel engine performance at altitudes above 1000 meters or in environments where ambient temperatures exceed 20°C and humidity goes over 30%, modifications to engine power should be made based on the manufacturer's detailed specifications.
Control Cabinet Operating Range:
- Power Voltage Fluctuation: Ensure your power supply remains stable within a fluctuation range of ≤±10% for reliable cabinet function.
- Ambient Temperature: Maintain a controlled environment with temperatures ranging from -10 to +40°C, ensuring it remains non-freezing for optimal cabinet operation.
- Air Relative Humidity: Maintain air humidity between 20% and 90%, ensuring no condensation forms to protect sensitive components.
Detailed Photos

Company Profile