Product Description
OVERVIEW
Introducing the GIMFLUID Centrifugal Fire Pump Set, part of the EDJ Series, a comprehensive and reliable Dual-Power Fire Pump System with esteemed CE certification. This expertly engineered solution combines an electric fire pump, a booster and pressure-regulating pump, a robust diesel fire pump, a pressure tank, and essential valves and pipelines, all meticulously integrated onto a single skid-mounted base. Designed for exceptional performance, this pump unit ensures unparalleled safety and reliability during emergency firefighting situations. Furthermore, the innovative diesel engine is equipped with advanced speed regulation capabilities, offering impressive adaptability across a broader spectrum of applications and precision adjustments for optimal equipment performance.
Product Parameters
PARAMETERS
- Flow Range: Experience a versatile flow range spanning from 10 to 1800 Liters per second, ensuring adaptability to your unique fire protection needs.
- Head Range: Enjoy the robust capability with a head range from 5 to 200 meters, designed to meet the most demanding fire safety requirements with ease.
- Working Pressure: Reliably operates within a working pressure range of 0.2 to 2.5 MPa, providing consistent performance under varied conditions.
- Power Supply: Features dual power supply options, seamlessly switching between electric and diesel, offering uninterrupted reliability in critical times.
Applications
APPLICATIONS
- Comprehensive Commercial Complexes: Tailored for the dynamic needs of multifaceted commercial environments.
- Hospitals, Schools, Office Buildings: Ensuring safety and reliability in essential community infrastructures.
- Industrial and Mining Enterprises: Engineered to withstand the rigorous demands of industrial operations.
- Large Warehouses: Providing robust protection for expansive spaces and critical inventory.
- Fire Hydrant Systems: An integral component for rapid response and fire control.
- Sprinkler Systems: Designed for unparalleled efficiency in automated fire suppression.
- Spray Cooling Systems: Innovative cooling solutions for thermal management and fire prevention.
- Foam Systems: Specialized in managing flammable liquid fires with precision and effectiveness.
- Water Cannon Systems: Exceptional performance for high-pressure firefighting challenges.
Detailed Photos


Advantages
ADVANTAGES
- CE Certification: Electric/Diesel/Jockey Fire Pump: This state-of-the-art system is skid-mounted and fully compliant with CE Certification standards, ensuring optimal safety and reliability.
- Diverse Starting Methods: This pump set is engineered with a suite of starting capabilities, including manual start, remote signal activation, automatic initiation, automatic cessation, and emergency manual start, allowing for unparalleled flexibility and control.
- Dual Operating Assurance: In critical moments, if the electric pump encounters a failure or during power outages, the system smartly transitions to the diesel fire pump, guaranteeing uninterrupted operation and enhanced safety.
- Automatic Operation Upon Fire Detection: Upon receiving a valid fire signal, should the electric pump be unable to start due to power issues or faults, the diesel pump will seamlessly and automatically take over. Once power is restored or the electric pump becomes operational, the system will intuitively revert to the electric pump, ensuring efficient operation.
- Fire Signal Feedback: The system is equipped to transmit fire signals directly to the fire control room, enabling remote monitoring and precise control, thereby enhancing readiness and response.
- Automatic Shutdown: Once the fire signal dissipates, the diesel fire pump is programmed to execute a delayed shutdown, ensuring a thorough and reliable cessation of operation.
- Self-Charging Voltage Regulation: The system boasts an automatic battery charging feature from mains power, which guarantees the unit remains in optimal operating condition at all times.
- Comprehensive Alarm and Protection System: Featuring an advanced alarm portfolio, it includes notifications for three start failures, overspeed, low oil pressure, booster oil pressure irregularities, high coolant temperature, low oil temperature, charging device malfunctions, and voltage anomalies, ensuring robust performance monitoring.
- Visual Display System: The intuitive control panel provides real-time data such as engine oil pressure, speed metrics, battery charging current, and voltage levels, offering a clear overview of operational status and aiding in prompt decision-making.
- Integrated Structure: Expertly designed, the diesel engine and pump are connected directly via a coupling on a unified steel base. This intelligent design fosters superior performance, minimizes faults, reduces vibration, and simplifies on-site installation, providing a robust and streamlined solution.
- Cost-Effective Construction: Compared to conventional pump houses with extensive concrete foundations and piping, the EDJ fire pump unit necessitates only the securing of its common base and the connection of inlet and outlet pipelines, substantially reducing project costs and complexity.
Company Profile






FAQ