XBC Series Diesel Fire Pump Unit The XBC Series Diesel Fire Pump Unit is a cutting-edge marvel that seamlessly combines the latest in industrial automation, information technology, and mechanical operations. This advanced unit is engineered to deliver superior performance and reliability, boasting the following exceptional features:
- Automatic Start and Stop: Experience peace of mind with its ability to initiate and halt operations automatically, ensuring seamless functionality without the need for manual intervention.
- Automatic Speed Regulation: Effortlessly adjusts its speed to meet varying demands, providing optimal performance at all times.
- Automatic Charging: Equipped with cutting-edge automatic charging capabilities, guaranteeing continuous power availability.
- Parameter Monitoring: Vigilantly monitors and detects vital parameters, offering real-time data for enhanced operational oversight.
- Automatic Alarming: Instantly alerts operators through automatic alarms, ensuring prompt response to any irregularities.
- Automatic Inspection: Conducts comprehensive inspections automatically, assuring consistent performance and safety.
- Remote Control: Empowers users with remote control functionalities, enabling convenient operation from any location.
APPLICATIONS
- Fire Protection Systems:
- Fire Hydrant Systems
- Sprinkler Systems
- Water Spray Cooling Systems
- Foam Systems
- Water Cannon Systems
- Hospital Fire Protection
- Emergency Fire Water Supply
- Fire Systems for Industrial and Civil Buildings
ADVANTAGES
- Multiple Startup Options: Designed with versatility in mind, this unit features a range of startup options, including manual start, activation via remote signal, automatic startup, and emergency manual direct start, ensuring it meets any operational need.
- Automatic Operation in Fire Situations: During a fire emergency, the diesel fire pump unit springs into automatic action upon receiving a valid fire signal. If the electric fire pump system faces power issues or malfunctions, the diesel unit takes over seamlessly. Once the power is restored or the electric pump resumes operation, the system switches back without any manual intervention.
- Fire Signal Feedback: Empowered with the ability to send responsive fire signals back to the control room, facilitating remote monitoring and command, enhancing safety and efficiency.
- Automatic Shutdown: Ensures safety and efficiency with its ability to automatically shut down following a fire signal disappearance, providing a delayed shutdown for maximum reliability.
- Self-Charging Voltage Regulation: Featuring an intelligent self-charging system, the unit's battery is instinctively charged via mains electricity, ensuring readiness and smooth starts.
- Comprehensive Alarm and Protection System: The unit is equipped with an extensive alarm and protection system, including alerts for start-up failures, overspeed, various pressure and temperature anomalies, and battery issues, securing both operation and personnel safety.
- Visualization Display System: The unit's state-of-the-art control panel provides a clear display of essential metrics such as diesel engine oil pressure, engine speed, and battery status, ensuring constant awareness of operational conditions.
- Integrated Structure: The unit boasts a sophisticated integrated design, with the diesel engine and pump coupled directly on a common steel base, promising superior performance and reliability while minimizing faults and vibrations for effortless on-site installation.
Product Parameters
TECHNICAL PARAMETER
Pump Operating Range:
- Flow Rate: 100-430 L/S
- Head: 60-185 m
- Transported Media: Handles ordinary clean water and firefighting foam liquid with ease, ensuring versatility and efficiency in diverse applications.
Diesel Engine Operating Range:
- Ambient Temperature: Operates effortlessly between -25 to 55°C, providing reliable performance across a wide temperature spectrum.
- Relative Humidity: Optimal performance maintained at humidity levels below 85%.
- Longitudinal Inclination: Engineered to function at inclinations under 10°, adapting to varied terrain conditions.
- No Conductive Dust, Corrosive Gases, or Explosive Hazards: Designed to operate safely in environments free from conductive dust or gases that pose risks to metal insulation or explosion hazards.
- Altitude and Humidity Adjustments: For ambient temperatures exceeding 20°C, with humidity levels over 30%, or at altitudes above 1000 meters, consult the manufacturer's data table to adjust the diesel engine power accordingly for optimal operation.
Control Cabinet Operating Range:
- Power Voltage Fluctuation: Efficiently manages power voltage fluctuations within a safe range of ≤±10%.
- Ambient Temperature: Functions seamlessly between -10 to +40°C, avoiding freezing conditions for stable operations.
- Air Relative Humidity: Operates optimally in air relative humidity ranging from 20% to 90%, ensuring no condensation for reliable performance.