Product Description
OVERVIEW
Introducing the unparalleled EDJ Series Fire Diesel Electric Fire Pump Unit, a masterful blend of innovation and reliability, proudly boasting CE certification. This cutting-edge dual-power fire pump system meticulously combines an electric fire pump, a booster, and pressure-regulating pump, alongside a diesel fire pump, a pressure tank, and all essential valves and pipelines, all artfully arranged on a singular skid-mounted base. Designed to deliver superior safety assurance, this remarkable pump unit is the quintessential choice for emergency firefighting scenarios. Furthermore, the diesel engine's advanced speed regulation capabilities enhance its versatility, catering to a broader spectrum of applications and enabling precise equipment adjustments. The EDJ Series is the embodiment of efficiency and flexibility, crafted to meet the dynamic demands of modern firefighting.
Product Parameters
PARAMETERS: Essential Insights into Performance
- Flow Range: Offering a dynamic flow from 10 to 1800 liters per second, ensuring versatility for varying demands.
- Head Range: Delivering a head range from 5 to an impressive 200 meters, catering to diverse operational needs.
- Working Pressure: Designed to withstand a working pressure from 0.2 to 2.5 MPa, ensuring robust performance under pressure.
- Power Supply: Equipped with a dual power supply for seamless and uninterrupted operation.
Applications
APPLICATIONS
- GIM Fluid Equipment (Shanghai) Co., Ltd. proudly presents the versatile Edj Jockey Fire Pump Set with Electric and Diesel Capabilities, perfectly suited for Comprehensive Commercial Complexes.
- Engineered for excellence, our fire pump set delivers unparalleled safety and reliability for Hospitals, Schools, Office Buildings, and more.
- From Industrial and Mining Enterprises to vast manufacturing plants, our innovative pump set meets the rigorous demands of heavy-duty operations.
- Designed to safeguard Large Warehouses, ensuring efficient and effective fire response when it matters the most.
- Integral to Fire Hydrant Systems, our advanced pump set guarantees optimal performance and swift action during emergencies.
- Our state-of-the-art pump set is ideal for Sprinkler Systems, providing robust protection and peace of mind.
- Experience enhanced safety with our Edj Jockey Fire Pump Set, tailored for Spray Cooling Systems, ensuring controlled cooling solutions.
- Perfectly adaptable for Foam Systems, our pump set offers powerful and efficient fire suppression capabilities.
- Capable of supporting Water Cannon Systems, our pump set showcases unmatched power and precision in fire control.
Detailed Photos


Advantages
ADVANTAGES
- CE Certification: Electric/Diesel/Jockey Fire Pump with skid-mounted design is meticulously engineered to comply with CE Certification standards, ensuring top-notch safety and quality.
- Multiple Starting Methods: Our system boasts a plethora of starting functionalities, including manual start, remote signal start, automatic start, automatic stop, and even emergency manual start, offering unparalleled flexibility and reliability.
- Dual Operating Assurance: To guarantee uninterrupted performance during emergencies, the system seamlessly switches to the diesel fire pump if the electric pump encounters a failure or there is a power outage, ensuring continuous protection.
- Automatic Operation on Fire Detection: Upon detecting a fire, if the electric pump is incapacitated due to a power fault, the diesel pump takes charge automatically. Once the electric pump is operational again, the system reverts effortlessly to the electric pump, ensuring efficient and reliable fire suppression.
- Fire Signal Feedback: The sophisticated system is capable of transmitting fire alerts directly to the fire control room, allowing for advanced remote monitoring and strategic control.
- Automatic Shutdown: The diesel fire pump features an intelligent delay shutdown mechanism that activates once the fire alert ceases, optimizing resource usage.
- Self-Charging Voltage Regulation: Thanks to automated charging from mains power, the battery remains in peak condition, ensuring that the unit operates seamlessly without interruptions.
- Comprehensive Alarm and Protection System: The alarm system is robust, covering scenarios like three consecutive start failures, overspeed conditions, low oil and booster oil pressures, high coolant temperatures, low oil temperatures, charging device faults, and varied battery voltage levels, safeguarding the unit's integrity.
- Visual Display System: Featuring a dynamic control panel that vividly displays crucial metrics such as engine oil pressure, engine speed, battery charging current, and voltage, providing real-time monitoring for optimal performance.
- Integrated Structure: The cutting-edge design incorporates a direct connection between the diesel engine and pump using a coupling on a unified steel base. This compact configuration enhances overall performance, minimizes malfunctions, reduces vibrations, and simplifies on-site installations.
- Low Construction Cost: The EDJ fire pump unit's innovative design allows for significant cost savings by eliminating the need for traditional concrete foundations and complex piping. Simply secure the common base and connect the inlet and outlet pipelines, cutting down on project expenses dramatically.
Company Profile