OVERVIEW
XBC Series Diesel Fire Pump Unit This high-tech masterpiece seamlessly integrates cutting-edge industrial automation control, sophisticated information processing, and advanced mechanical operation technologies. Revel in its outstanding features:
- Automatic Start and Stop: Experience seamless operations with automatic start and stop capabilities, ensuring your system is always ready at a moment's notice for ultimate protection.
- Automatic Speed Regulation: Effortlessly adjusts speed to suit operational demands, optimizing both efficiency and performance to the highest standards.
- Automatic Charging: Stay powered and prepared with built-in automatic charging capabilities, ensuring your system is always at peak readiness.
- Parameter Monitoring: Vigilantly monitors and detects essential parameters to maintain optimal functionality and seamless operation.
- Automatic Alarming: Provides timely, automatic alarms, keeping you informed and alert to ensure proactive responses.
- Automatic Inspection: Performs thorough automatic inspections, guaranteeing everything is in top-notch order and functioning seamlessly.
- Remote Control: Enjoy the convenience and flexibility of remote control operations, ensuring ease of management from anywhere.
APPLICATIONS
- Fire Protection Systems:
- Fire Hydrant Systems
- Sprinkler Systems
- Water Spray Cooling Systems
- Foam Systems
- Water Cannon Systems
- Hospital Fire Protection
- Emergency Fire Water Supply
- Fire Systems for Industrial and Civil Buildings
ADVANTAGES
- Multiple Startup Options: Boasts an array of startup functions including manual start, remote signal activation, automatic startup, and emergency manual direct start, ensuring unmatched versatility and reliability.
- Automatic Operation in Fire Situations: Automatically springs into action upon receiving a valid fire signal, even compensating for power failures, phase loss, or pump malfunctions. Effortlessly switches back to electric mode once systems are restored, ensuring unwavering fire protection and peace of mind.
- Fire Signal Feedback: Seamlessly sends fire signals back to the control room, enhancing remote monitoring and operational oversight for superior management.
- Automatic Shutdown: Efficiently shuts down with a delay post-signal disappearance, conserving resources and ensuring safety without compromising performance.
- Self-Charging Voltage Regulation: Automatically charges using mains electricity, guaranteeing reliable unit start-up and continuous operation for uninterrupted protection.
- Comprehensive Alarm and Protection System: Features a robust system of alarms for various issues such as startup failures, overspeed, oil pressure anomalies, coolant temperature spikes, charging failures, and battery voltage irregularities, ensuring comprehensive protection and heightened awareness.
- Visualization Display System: Stay informed with a control panel that vividly displays crucial information like oil pressure, engine speed, charging current, and voltage, providing clear and instant insights.
- Integrated Structure: Ingeniously crafted with a direct coupling between the diesel engine and pump on a shared steel base, this compact and efficient design promises exceptional performance with minimal vibrations and faults, facilitating easy and hassle-free on-site installation.
Product Parameters
TECHNICAL PARAMETER
Pump Operating Range:
- Flow Rate: 100-430 L/S
- Head: 60-185 m
- Transported Media: Designed to handle ordinary clean water as well as specialized firefighting foam liquid, ensuring versatile and effective firefighting capabilities.
Diesel Engine Operating Range:
- Ambient Temperature: Operates efficiently in temperature ranges from -25 to 55°C, providing reliable performance in varied climates.
- Relative Humidity: Capable of operating in environments with a relative humidity of less than 85%, ensuring consistent functionality.
- Longitudinal Inclination: Designed for stability, withstanding inclinations of less than 10°, ideal for diverse installation scenarios.
- No Conductive Dust, Corrosive Gases, or Explosive Hazards: This system is crafted to avoid environments with conductive dust or gases that can damage metal insulation or pose explosion risks, ensuring maximum safety and reliability.
- Altitude and Humidity Adjustments: For optimal performance, adjust the diesel engine power based on conditions: ambient temperatures above 20°C, relative humidity over 30%, or altitudes exceeding 1000 meters, following the manufacturer's detailed data table.
Control Cabinet Operating Range:
- Power Voltage Fluctuation: Handles power voltage fluctuations of up to ≤±10%, maintaining stable operation in varied electrical conditions.
- Ambient Temperature: Designed to function optimally in temperatures ranging from -10 to +40°C, ensuring performance even in non-freezing conditions.
- Air Relative Humidity: Operates effectively with air relative humidity between 20% to 90%, preventing condensation to safeguard reliability and longevity.